Static convertor SSVC - 13 |
|
Static
converter for auxiliary services in 1st class coaches (with air
conditioning). |
|
technical specifications |
|
|
Input voltage:
1500Vac (-30%...+25%) / 50Hz (±2%) |
|
|
Maximum current: 65A |
|
|
Minimum efficiency: 86% |
|
|
Adjustable voltage for batteries charging: 28Vdc (±2%) |
|
|
Output voltage according
to UIC requirements |
|
|
Output voltage is ambient
temperature dependant: 0,06Vdc / °C |
|
|
Maximum charging voltage:
30Vdc |
|
|
Batteries charging limited current: 80Adc (±5%) |
|
|
Total limited current: 200Adc (±5%) |
|
|
Output voltage: 230
Vac (±8%) / 50Hz (±1%) |
|
|
Sinusoidal waveform
THD <3% |
|
|
Rated power (cos fi = 0.8):
16,2kW |
|
|
Maximum current:
55A |
|
|
Output voltage: 3
x 400 Vac (±5%)/ 50Hz (±1%) |
|
|
Sinusoidal waveform
THD < 8% |
|
|
Rated power (cos fi = 0.8):
32kVA |
|
|
Maximum power (for 5
seconds): 70kVA |
|
|
Auxiliary voltage: 1500
Vac (-30%..+20%) / 50Hz (±1%) |
|
|
Rated power (cos fi = 0.8):
38kVA |
|
|
Short-circuit protection
through incorporated fuse |
|
references |
|
|
Code UIC, 550 OR, Installations pour
l'alimentation en énergie électrique du matériel a voyageurs. |
|
dimensions |
|
|
L x l x h = mm |
|
|
weight = ± kg |
|
< back |
|